![]() ![]() V
640
520
250
93
640
520
Conversion Terms:
LampUF & PC
OLY 150S/R/A150W SON-E1.00
OLY 150SP/R/A150W SON-PE1.00
SHR NOM =1.25
Reflectances
Room Index
CWF
0.751.001.251.502.002.503.004.005.0
0.700.500.20
0.420.440.480.500.540.560.580.610.6
0.30
0.380.400.440.470.510.530.550.580.6
0.10
0.360.370.410.440.480.510.530.560.5
0.500.500.20
0.410.430.460.490.520.540.560.580.5
0.30
0.380.400.430.460.490.520.530.560.5
0.10
0.350.370.400.430.470.490.510.540.5
0.300.500.20
0.400.420.450.470.500.520.540.550.5
0.30
0.370.390.420.440.480.500.520.540.5
0.10
0.350.360.400.420.460.480.500.530.5
0.000.000.00
0.340.350.380.400.430.460.470.500.5
BZ Class
233334444
DF(F)
0.340.350.380.400.430.460.470.500.5
DF(W)
0.250.240.210.190.150.130.110.090.0
DF(C)
0.010.010.010.010.010.010.010.010.0
DF(V)
Cylindrical
0.050.060.070.080.100.110.120.140.1
DF(S)
Scalar
0.090.100.110.120.140.150.160.170.1
0.02
5980919860
1.41
0.60
1.49
0.59
0.01
Olympia Range
Description:
150W recessed canopy fitting with acrylic prismatic lens
Vandalite Lighting Ltd
Photometric Data Sheet
Cartesian Diagram
0
50
100
150
200
250
300
350
Gamma Angle
TransverseAxial
Dimensions:
(in mm)
Physical Width =
Luminous Width =
Physical Height =
Luminous Height =
Physical Length =
Luminous Length =
Flux Fraction Ratio =
SHR MAX =
SHR MAX(TR) =
CIE Flux Code =
Light Output Ratio =
Downward LOR =
Upward LOR =
/ / / /
Utilisation Factors - UF(F)
Floor Reflectance - 20%
![]() 0
297297
0
0.0000.00
5
287321
5
0.0910.00
10
270327
10
0.1850.01
15
264283
15
0.2730.03
20
290235
20
0.3450.05
25
289226
25
0.4080.08
30
230225
30
0.4670.11
35
189191
35
0.5180.14
40
136157
40
0.5590.17
45
90118
45
0.5890.20
50
6788
50
0.6090.22
55
5770
55
0.6230.24
60
5059
60
0.6330.26
65
4452
65
0.6410.27
70
3942
70
0.6460.29
75
3433
75
0.6500.30
80
2924
80
0.6510.30
85
2418
85
0.6520.31
90
1712
90
0.6520.32
95
107
100
53
105
32
110
22
115
11
120
11
125
00
130
00
135
00
140
00
45
39952
145
00
50
31841
150
00
55
29336
155
00
60
28233
160
00
65
27832
165
00
70
28330
170
00
75
29128
175
00
80
30725
180
00
85
33525
OLY001A
Luminous Intensity Values - (cd/1000 lm)
Gamma Angle Transverse Axial
(degrees) Plane (0) Plane (90)
o
o
Angle Parallel Perpendicular
(degrees) Plane Plane
Aspect Factors
Angle Transverse Axial
(degrees) Plane Plane
Luminance Distribution (cd/m/klm)
2
TheUtilisationFactortable,BZvalues,andDistributionFactors(F)(W)&(C)havebeencalculatedinaccordancewithCIBSETechnicalMemorandumNo.5
(1980
fro
datatestedwithoutaceilingboard.TheUFvaluesneedtobecorrectedusingtheappropriateconversionfactor.TheDistributionFactorsforcylindricalandscala
illuminance have been calculated using data provided by Dr. A. R. Bean.
Allinformation,recommendations,oradvicecontainedinthisdocumentorgivenbyVandaliteLightingLtd.,oranyofitssubsidiaries,affiliates,orauthorise
representatives, whether written or oral, is given in good faith, to the best of its knowledge, and based on current procedures in effect.
TheproductsofVandaliteLightingLtd.orifapplicable,ofitssubsidiariesoraffiliatesaresoldsubjecttoGeneralConditionsofSaleprintedattherearofthe
curren
catalogueoravailableuponrequest.Nothinginthisoranyotherdocumentshallalter,varyorsupersede,oroperatetowaiveanyoftheGeneralConditionsofSale.Eac
useroftheproductsshallconvincethemselves,throughallavailablesources(includingfinishedproducttestinginitsappropriateenvironment)ofthesuitabilityofth
productssuppliedforitsownparticularpurpose.BecauseactualuseoftheproductsbytheuserisbeyondthecontrolofVandaliteLightingLtd.,itssubsidiariesan
affiliates,suchuseiswithintheexclusiveresponsibilityoftheuser.VandaliteLightingLtd.,itssubsidiariesandaffiliatescannotbeheldresponsibleforanylossincurre
throughincorrectorfaultyuseoftheproducts.Information,recommendationand/oradviceareneithermadetoinfringeonanypatents,nortograntalicenseunderan
patentorintellectualpropertyrightofVandaliteLightingLtdoranyofitssubsidiariesoraffiliatedcompanies,nortogranttherighttofileforanypatentprotection.We
hav
a policy of continuous technical development and products and / or descriptions, and / or materials may be changed without prior public announcement or warning.
Photometric Data Sheet Reference:
![]() ![]() V
640
520
250
93
640
520
Conversion Terms:
LampUF & PC
OLY 250S/R/A250W SON-E1.00
OLY 250SP/R/A250W SON-PE1.00
OLY 250M/R/A250W MBF-U1.00
OLY 250MH/R/A
250W HQI-E1.00
SHR NOM =1.25
Reflectances
Room Index
CWF
0.751.001.251.502.002.503.004.005.0
0.700.500.20
0.410.430.470.490.530.550.570.590.6
0.30
0.380.400.430.460.500.520.540.570.5
0.10
0.350.370.400.430.470.500.520.550.5
0.500.500.20
0.400.420.450.480.510.530.550.570.5
0.30
0.370.390.420.450.480.510.520.550.5
0.10
0.350.360.400.420.460.480.500.530.5
0.300.500.20
0.390.410.440.460.490.510.520.540.5
0.30
0.360.380.410.430.470.490.510.530.5
0.10
0.340.360.390.410.450.470.490.510.5
0.000.000.00
0.330.340.370.390.430.450.460.490.5
BZ Class
233344444
DF(F)
0.330.340.370.390.430.450.460.490.5
DF(W)
0.250.240.200.180.150.130.110.090.0
DF(C)
0.010.010.010.010.010.010.010.010.0
DF(V)
Cylindrical
0.050.060.070.080.100.110.120.130.1
DF(S)
Scalar
0.090.100.110.120.140.150.160.170.1
0.02
5980919859
1.41
0.59
1.49
0.58
0.01
Olympia Range
Description:
250W recessed canopy fitting with acrylic prismatic lens
Vandalite Lighting Ltd
Photometric Data Sheet
Cartesian Diagram
0
50
100
150
200
250
300
350
Gamma Angle
TransverseAxial
Dimensions:
(in mm)
Physical Width =
Luminous Width =
Physical Height =
Luminous Height =
Physical Length =
Luminous Length =
Flux Fraction Ratio =
SHR MAX =
SHR MAX(TR) =
CIE Flux Code =
Light Output Ratio =
Downward LOR =
Upward LOR =
/ / / /
Utilisation Factors - UF(F)
Floor Reflectance - 20%
![]() 0
291291
0
0.0000.00
5
281315
5
0.0910.00
10
265320
10
0.1850.01
15
259277
15
0.2730.03
20
284230
20
0.3450.05
25
283221
25
0.4080.08
30
225221
30
0.4670.11
35
185187
35
0.5180.14
40
133154
40
0.5590.17
45
88116
45
0.5890.20
50
6686
50
0.6090.22
55
5669
55
0.6230.24
60
4958
60
0.6340.26
65
4351
65
0.6410.27
70
3841
70
0.6460.29
75
3332
75
0.6500.30
80
2824
80
0.6510.31
85
2418
85
0.6520.31
90
1712
90
0.6520.32
95
107
100
53
105
32
110
22
115
11
120
11
125
00
130
00
135
00
140
00
45
39051
145
00
50
31340
150
00
55
28835
155
00
60
27732
160
00
65
27232
165
00
70
27629
170
00
75
28327
175
00
80
29625
180
00
85
33525
OLY001B
Luminous Intensity Values - (cd/1000 lm)
Gamma Angle Transverse Axial
(degrees) Plane (0) Plane (90)
o
o
Angle Parallel Perpendicular
(degrees) Plane Plane
Aspect Factors
Angle Transverse Axial
(degrees) Plane Plane
Luminance Distribution (cd/m/klm)
2
TheUtilisationFactortable,BZvalues,andDistributionFactors(F)(W)&(C)havebeencalculatedinaccordancewithCIBSETechnicalMemorandumNo.5
(1980
fro
datatestedwithoutaceilingboard.TheUFvaluesneedtobecorrectedusingtheappropriateconversionfactor.TheDistributionFactorsforcylindricalandscala
illuminance have been calculated using data provided by Dr. A. R. Bean.
Allinformation,recommendations,oradvicecontainedinthisdocumentorgivenbyVandaliteLightingLtd.,oranyofitssubsidiaries,affiliates,orauthorise
representatives, whether written or oral, is given in good faith, to the best of its knowledge, and based on current procedures in effect.
TheproductsofVandaliteLightingLtd.orifapplicable,ofitssubsidiariesoraffiliatesaresoldsubjecttoGeneralConditionsofSaleprintedattherearofthe
curren
catalogueoravailableuponrequest.Nothinginthisoranyotherdocumentshallalter,varyorsupersede,oroperatetowaiveanyoftheGeneralConditionsofSale.Eac
useroftheproductsshallconvincethemselves,throughallavailablesources(includingfinishedproducttestinginitsappropriateenvironment)ofthesuitabilityofth
productssuppliedforitsownparticularpurpose.BecauseactualuseoftheproductsbytheuserisbeyondthecontrolofVandaliteLightingLtd.,itssubsidiariesan
affiliates,suchuseiswithintheexclusiveresponsibilityoftheuser.VandaliteLightingLtd.,itssubsidiariesandaffiliatescannotbeheldresponsibleforanylossincurre
throughincorrectorfaultyuseoftheproducts.Information,recommendationand/oradviceareneithermadetoinfringeonanypatents,nortograntalicenseunderan
patentorintellectualpropertyrightofVandaliteLightingLtdoranyofitssubsidiariesoraffiliatedcompanies,nortogranttherighttofileforanypatentprotection.We
hav
a policy of continuous technical development and products and / or descriptions, and / or materials may be changed without prior public announcement or warning.
Photometric Data Sheet Reference:
![]() ![]() V
640
520
250
93
640
520
Conversion Terms:
LampUF & PC
OLY 400S/R/A400W SON-E1.00
OLY 400SP/R/A400W SON-PE1.00
OLY 400M/R/A400W MBF-U1.00
OLY 400MH/R/A
400W HQI-E1.00
SHR NOM =1.25
Reflectances
Room Index
CWF
0.751.001.251.502.002.503.004.005.0
0.700.500.20
0.400.430.460.480.520.540.560.580.6
0.30
0.370.390.420.450.490.510.530.560.5
0.10
0.340.360.390.420.460.490.510.540.5
0.500.500.20
0.390.410.440.470.500.520.540.560.5
0.30
0.360.380.410.440.470.500.510.540.5
0.10
0.340.350.390.410.450.470.490.520.5
0.300.500.20
0.390.400.430.450.480.500.510.530.5
0.30
0.360.370.400.430.460.480.500.520.5
0.10
0.340.350.380.400.440.460.480.500.5
0.000.000.00
0.320.330.360.390.420.440.450.480.4
BZ Class
233344444
DF(F)
0.320.330.360.390.420.440.450.480.4
DF(W)
0.240.230.200.180.150.130.110.090.0
DF(C)
0.010.010.010.010.010.010.010.010.0
DF(V)
Cylindrical
0.050.060.070.080.090.110.120.130.1
DF(S)
Scalar
0.090.100.110.120.130.140.150.170.1
0.02
5980919858
1.41
0.58
1.49
0.56
0.01
Olympia Range
Description:
400W recessed canopy fitting with acrylic prismatic lens
Vandalite Lighting Ltd
Photometric Data Sheet
Cartesian Diagram
0
50
100
150
200
250
300
350
Gamma Angle
TransverseAxial
Dimensions:
(in mm)
Physical Width =
Luminous Width =
Physical Height =
Luminous Height =
Physical Length =
Luminous Length =
Flux Fraction Ratio =
SHR MAX =
SHR MAX(TR) =
CIE Flux Code =
Light Output Ratio =
Downward LOR =
Upward LOR =
/ / / /
Utilisation Factors - UF(F)
Floor Reflectance - 20%
![]() 0
285285
0
0.0000.00
5
276308
5
0.0910.00
10
259314
10
0.1850.01
15
253272
15
0.2730.03
20
278226
20
0.3460.05
25
277217
25
0.4080.08
30
221216
30
0.4670.11
35
181183
35
0.5190.14
40
131151
40
0.5590.17
45
86113
45
0.5890.20
50
6484
50
0.6090.22
55
5567
55
0.6240.24
60
4857
60
0.6340.26
65
4250
65
0.6410.27
70
3740
70
0.6470.29
75
3332
75
0.6500.30
80
2823
80
0.6520.31
85
2317
85
0.6520.31
90
1612
90
0.6530.32
95
107
100
53
105
32
110
22
115
11
120
11
125
00
130
00
135
00
140
00
45
38250
145
00
50
30439
150
00
55
28234
155
00
60
27132
160
00
65
26631
165
00
70
26829
170
00
75
28327
175
00
80
29624
180
00
85
32123
OLY001C
Luminous Intensity Values - (cd/1000 lm)
Gamma Angle Transverse Axial
(degrees) Plane (0) Plane (90)
o
o
Angle Parallel Perpendicular
(degrees) Plane Plane
Aspect Factors
Angle Transverse Axial
(degrees) Plane Plane
Luminance Distribution (cd/m/klm)
2
TheUtilisationFactortable,BZvalues,andDistributionFactors(F)(W)&(C)havebeencalculatedinaccordancewithCIBSETechnicalMemorandumNo.5
(1980
fro
datatestedwithoutaceilingboard.TheUFvaluesneedtobecorrectedusingtheappropriateconversionfactor.TheDistributionFactorsforcylindricalandscala
illuminance have been calculated using data provided by Dr. A. R. Bean.
Allinformation,recommendations,oradvicecontainedinthisdocumentorgivenbyVandaliteLightingLtd.,oranyofitssubsidiaries,affiliates,orauthorise
representatives, whether written or oral, is given in good faith, to the best of its knowledge, and based on current procedures in effect.
TheproductsofVandaliteLightingLtd.orifapplicable,ofitssubsidiariesoraffiliatesaresoldsubjecttoGeneralConditionsofSaleprintedattherearofthe
curren
catalogueoravailableuponrequest.Nothinginthisoranyotherdocumentshallalter,varyorsupersede,oroperatetowaiveanyoftheGeneralConditionsofSale.Eac
useroftheproductsshallconvincethemselves,throughallavailablesources(includingfinishedproducttestinginitsappropriateenvironment)ofthesuitabilityofth
productssuppliedforitsownparticularpurpose.BecauseactualuseoftheproductsbytheuserisbeyondthecontrolofVandaliteLightingLtd.,itssubsidiariesan
affiliates,suchuseiswithintheexclusiveresponsibilityoftheuser.VandaliteLightingLtd.,itssubsidiariesandaffiliatescannotbeheldresponsibleforanylossincurre
throughincorrectorfaultyuseoftheproducts.Information,recommendationand/oradviceareneithermadetoinfringeonanypatents,nortograntalicenseunderan
patentorintellectualpropertyrightofVandaliteLightingLtdoranyofitssubsidiariesoraffiliatedcompanies,nortogranttherighttofileforanypatentprotection.We
hav
a policy of continuous technical development and products and / or descriptions, and / or materials may be changed without prior public announcement or warning.
Photometric Data Sheet Reference:
![]() ![]() V
640
520
343
93
640
520
Conversion Terms:
LampUF & PC
OLY 150S/S/A150W SON-E1.00
OLY 150SP/S/A150W SON-PE1.00
SHR NOM =1.25
Reflectances
Room Index
CWF
0.751.001.251.502.002.503.004.005.0
0.700.500.20
0.420.440.480.500.540.560.580.610.6
0.30
0.380.400.440.470.510.530.550.580.6
0.10
0.360.370.410.440.480.510.530.560.5
0.500.500.20
0.410.430.460.490.520.540.560.580.5
0.30
0.380.400.430.460.490.520.530.560.5
0.10
0.350.370.400.430.470.490.510.540.5
0.300.500.20
0.400.420.450.470.500.520.540.550.5
0.30
0.370.390.420.440.480.500.520.540.5
0.10
0.350.360.400.420.460.480.500.530.5
0.000.000.00
0.340.350.380.400.430.460.470.500.5
BZ Class
233334444
DF(F)
0.340.350.380.400.430.460.470.500.5
DF(W)
0.250.240.210.190.150.130.110.090.0
DF(C)
0.010.010.010.010.010.010.010.010.0
DF(V)
Cylindrical
0.050.060.070.080.100.110.120.140.1
DF(S)
Scalar
0.090.100.110.120.140.150.160.170.1
0.02
5980919860
1.41
0.60
1.49
0.59
0.01
Olympia Range
Description:
150W surface canopy fitting with acrylic prismatic lens
Vandalite Lighting Ltd
Photometric Data Sheet
Cartesian Diagram
0
50
100
150
200
250
300
350
Gamma Angle
TransverseAxial
Dimensions:
(in mm)
Physical Width =
Luminous Width =
Physical Height =
Luminous Height =
Physical Length =
Luminous Length =
Flux Fraction Ratio =
SHR MAX =
SHR MAX(TR) =
CIE Flux Code =
Light Output Ratio =
Downward LOR =
Upward LOR =
/ / / /
Utilisation Factors - UF(F)
Floor Reflectance - 20%
![]() 0
297297
0
0.0000.00
5
287321
5
0.0910.00
10
270327
10
0.1850.01
15
264283
15
0.2730.03
20
290235
20
0.3450.05
25
289226
25
0.4080.08
30
230225
30
0.4670.11
35
189191
35
0.5180.14
40
136157
40
0.5590.17
45
90118
45
0.5890.20
50
6788
50
0.6090.22
55
5770
55
0.6230.24
60
5059
60
0.6330.26
65
4452
65
0.6410.27
70
3942
70
0.6460.29
75
3433
75
0.6500.30
80
2924
80
0.6510.30
85
2418
85
0.6520.31
90
1712
90
0.6520.32
95
107
100
53
105
32
110
22
115
11
120
11
125
00
130
00
135
00
140
00
45
39952
145
00
50
31841
150
00
55
29336
155
00
60
28233
160
00
65
27832
165
00
70
28330
170
00
75
29128
175
00
80
30725
180
00
85
33525
OLY002A
Luminous Intensity Values - (cd/1000 lm)
Gamma Angle Transverse Axial
(degrees) Plane (0) Plane (90)
o
o
Angle Parallel Perpendicular
(degrees) Plane Plane
Aspect Factors
Angle Transverse Axial
(degrees) Plane Plane
Luminance Distribution (cd/m/klm)
2
TheUtilisationFactortable,BZvalues,andDistributionFactors(F)(W)&(C)havebeencalculatedinaccordancewithCIBSETechnicalMemorandumNo.5
(1980
fro
datatestedwithoutaceilingboard.TheUFvaluesneedtobecorrectedusingtheappropriateconversionfactor.TheDistributionFactorsforcylindricalandscala
illuminance have been calculated using data provided by Dr. A. R. Bean.
Allinformation,recommendations,oradvicecontainedinthisdocumentorgivenbyVandaliteLightingLtd.,oranyofitssubsidiaries,affiliates,orauthorise
representatives, whether written or oral, is given in good faith, to the best of its knowledge, and based on current procedures in effect.
TheproductsofVandaliteLightingLtd.orifapplicable,ofitssubsidiariesoraffiliatesaresoldsubjecttoGeneralConditionsofSaleprintedattherearofthe
curren
catalogueoravailableuponrequest.Nothinginthisoranyotherdocumentshallalter,varyorsupersede,oroperatetowaiveanyoftheGeneralConditionsofSale.Eac
useroftheproductsshallconvincethemselves,throughallavailablesources(includingfinishedproducttestinginitsappropriateenvironment)ofthesuitabilityofth
productssuppliedforitsownparticularpurpose.BecauseactualuseoftheproductsbytheuserisbeyondthecontrolofVandaliteLightingLtd.,itssubsidiariesan
affiliates,suchuseiswithintheexclusiveresponsibilityoftheuser.VandaliteLightingLtd.,itssubsidiariesandaffiliatescannotbeheldresponsibleforanylossincurre
throughincorrectorfaultyuseoftheproducts.Information,recommendationand/oradviceareneithermadetoinfringeonanypatents,nortograntalicenseunderan
patentorintellectualpropertyrightofVandaliteLightingLtdoranyofitssubsidiariesoraffiliatedcompanies,nortogranttherighttofileforanypatentprotection.We
hav
a policy of continuous technical development and products and / or descriptions, and / or materials may be changed without prior public announcement or warning.
Photometric Data Sheet Reference:
![]() ![]() V
640
520
250
93
640
520
Conversion Terms:
LampUF & PC
OLY 250S/S/A250W SON-E1.00
OLY 250SP/S/A250W SON-PE1.00
OLY 250M/S/A250W MBF-U1.00
OLY 250MH/S/A
250W HQI-E1.00
SHR NOM =1.25
Reflectances
Room Index
CWF
0.751.001.251.502.002.503.004.005.0
0.700.500.20
0.410.430.470.490.530.550.570.590.6
0.30
0.380.400.430.460.500.520.540.570.5
0.10
0.350.370.400.430.470.500.520.550.5
0.500.500.20
0.400.420.450.480.510.530.550.570.5
0.30
0.370.390.420.450.480.510.520.550.5
0.10
0.350.360.400.420.460.480.500.530.5
0.300.500.20
0.390.410.440.460.490.510.520.540.5
0.30
0.360.380.410.430.470.490.510.530.5
0.10
0.340.360.390.410.450.470.490.510.5
0.000.000.00
0.330.340.370.390.430.450.460.490.5
BZ Class
233344444
DF(F)
0.330.340.370.390.430.450.460.490.5
DF(W)
0.250.240.200.180.150.130.110.090.0
DF(C)
0.010.010.010.010.010.010.010.010.0
DF(V)
Cylindrical
0.050.060.070.080.100.110.120.130.1
DF(S)
Scalar
0.090.100.110.120.140.150.160.170.1
0.02
5980919859
1.41
0.59
1.49
0.58
0.01
Olympia Range
Description:
250W surface canopy fitting with acrylic prismatic lens
Vandalite Lighting Ltd
Photometric Data Sheet
Cartesian Diagram
0
50
100
150
200
250
300
350
Gamma Angle
TransverseAxial
Dimensions:
(in mm)
Physical Width =
Luminous Width =
Physical Height =
Luminous Height =
Physical Length =
Luminous Length =
Flux Fraction Ratio =
SHR MAX =
SHR MAX(TR) =
CIE Flux Code =
Light Output Ratio =
Downward LOR =
Upward LOR =
/ / / /
Utilisation Factors - UF(F)
Floor Reflectance - 20%
![]() 0
291291
0
0.0000.00
5
281315
5
0.0910.00
10
265320
10
0.1850.01
15
259277
15
0.2730.03
20
284230
20
0.3450.05
25
283221
25
0.4080.08
30
225221
30
0.4670.11
35
185187
35
0.5180.14
40
133154
40
0.5590.17
45
88116
45
0.5890.20
50
6686
50
0.6090.22
55
5669
55
0.6230.24
60
4958
60
0.6340.26
65
4351
65
0.6410.27
70
3841
70
0.6460.29
75
3332
75
0.6500.30
80
2824
80
0.6510.31
85
2418
85
0.6520.31
90
1712
90
0.6520.32
95
107
100
53
105
32
110
22
115
11
120
11
125
00
130
00
135
00
140
00
45
39051
145
00
50
31340
150
00
55
28835
155
00
60
27732
160
00
65
27232
165
00
70
27629
170
00
75
28327
175
00
80
29625
180
00
85
33525
OLY002B
Luminous Intensity Values - (cd/1000 lm)
Gamma Angle Transverse Axial
(degrees) Plane (0) Plane (90)
o
o
Angle Parallel Perpendicular
(degrees) Plane Plane
Aspect Factors
Angle Transverse Axial
(degrees) Plane Plane
Luminance Distribution (cd/m/klm)
2
TheUtilisationFactortable,BZvalues,andDistributionFactors(F)(W)&(C)havebeencalculatedinaccordancewithCIBSETechnicalMemorandumNo.5
(1980
fro
datatestedwithoutaceilingboard.TheUFvaluesneedtobecorrectedusingtheappropriateconversionfactor.TheDistributionFactorsforcylindricalandscala
illuminance have been calculated using data provided by Dr. A. R. Bean.
Allinformation,recommendations,oradvicecontainedinthisdocumentorgivenbyVandaliteLightingLtd.,oranyofitssubsidiaries,affiliates,orauthorise
representatives, whether written or oral, is given in good faith, to the best of its knowledge, and based on current procedures in effect.
TheproductsofVandaliteLightingLtd.orifapplicable,ofitssubsidiariesoraffiliatesaresoldsubjecttoGeneralConditionsofSaleprintedattherearofthe
curren
catalogueoravailableuponrequest.Nothinginthisoranyotherdocumentshallalter,varyorsupersede,oroperatetowaiveanyoftheGeneralConditionsofSale.Eac
useroftheproductsshallconvincethemselves,throughallavailablesources(includingfinishedproducttestinginitsappropriateenvironment)ofthesuitabilityofth
productssuppliedforitsownparticularpurpose.BecauseactualuseoftheproductsbytheuserisbeyondthecontrolofVandaliteLightingLtd.,itssubsidiariesan
affiliates,suchuseiswithintheexclusiveresponsibilityoftheuser.VandaliteLightingLtd.,itssubsidiariesandaffiliatescannotbeheldresponsibleforanylossincurre
throughincorrectorfaultyuseoftheproducts.Information,recommendationand/oradviceareneithermadetoinfringeonanypatents,nortograntalicenseunderan
patentorintellectualpropertyrightofVandaliteLightingLtdoranyofitssubsidiariesoraffiliatedcompanies,nortogranttherighttofileforanypatentprotection.We
hav
a policy of continuous technical development and products and / or descriptions, and / or materials may be changed without prior public announcement or warning.
Photometric Data Sheet Reference:
![]() ![]() V
640
520
250
93
640
520
Conversion Terms:
LampUF & PC
OLY 400S/S/A400W SON-E1.00
OLY 400SP/S/A400W SON-PE1.00
OLY 400M/S/A400W MBF-U1.00
OLY 400MH/S/A
400W HQI-E1.00
SHR NOM =1.25
Reflectances
Room Index
CWF
0.751.001.251.502.002.503.004.005.0
0.700.500.20
0.400.430.460.480.520.540.560.580.6
0.30
0.370.390.420.450.490.510.530.560.5
0.10
0.340.360.390.420.460.490.510.540.5
0.500.500.20
0.390.410.440.470.500.520.540.560.5
0.30
0.360.380.410.440.470.500.510.540.5
0.10
0.340.350.390.410.450.470.490.520.5
0.300.500.20
0.390.400.430.450.480.500.510.530.5
0.30
0.360.370.400.430.460.480.500.520.5
0.10
0.340.350.380.400.440.460.480.500.5
0.000.000.00
0.320.330.360.390.420.440.450.480.4
BZ Class
233344444
DF(F)
0.320.330.360.390.420.440.450.480.4
DF(W)
0.240.230.200.180.150.130.110.090.0
DF(C)
0.010.010.010.010.010.010.010.010.0
DF(V)
Cylindrical
0.050.060.070.080.090.110.120.130.1
DF(S)
Scalar
0.090.100.110.120.130.140.150.170.1
0.02
5980919858
1.41
0.58
1.49
0.56
0.01
Olympia Range
Description:
400W surface canopy fitting with acrylic prismatic lens
Vandalite Lighting Ltd
Photometric Data Sheet
Cartesian Diagram
0
50
100
150
200
250
300
350
Gamma Angle
TransverseAxial
Dimensions:
(in mm)
Physical Width =
Luminous Width =
Physical Height =
Luminous Height =
Physical Length =
Luminous Length =
Flux Fraction Ratio =
SHR MAX =
SHR MAX(TR) =
CIE Flux Code =
Light Output Ratio =
Downward LOR =
Upward LOR =
/ / / /
Utilisation Factors - UF(F)
Floor Reflectance - 20%
![]() 0
285285
0
0.0000.00
5
276308
5
0.0910.00
10
259314
10
0.1850.01
15
253272
15
0.2730.03
20
278226
20
0.3460.05
25
277217
25
0.4080.08
30
221216
30
0.4670.11
35
181183
35
0.5190.14
40
131151
40
0.5590.17
45
86113
45
0.5890.20
50
6484
50
0.6090.22
55
5567
55
0.6240.24
60
4857
60
0.6340.26
65
4250
65
0.6410.27
70
3740
70
0.6470.29
75
3332
75
0.6500.30
80
2823
80
0.6520.31
85
2317
85
0.6520.31
90
1612
90
0.6530.32
95
107
100
53
105
32
110
22
115
11
120
11
125
00
130
00
135
00
140
00
45
38250
145
00
50
30439
150
00
55
28234
155
00
60
27132
160
00
65
26631
165
00
70
26829
170
00
75
28327
175
00
80
29624
180
00
85
32123
OLY002C
Luminous Intensity Values - (cd/1000 lm)
Gamma Angle Transverse Axial
(degrees) Plane (0) Plane (90)
o
o
Angle Parallel Perpendicular
(degrees) Plane Plane
Aspect Factors
Angle Transverse Axial
(degrees) Plane Plane
Luminance Distribution (cd/m/klm)
2
TheUtilisationFactortable,BZvalues,andDistributionFactors(F)(W)&(C)havebeencalculatedinaccordancewithCIBSETechnicalMemorandumNo.5
(1980
fro
datatestedwithoutaceilingboard.TheUFvaluesneedtobecorrectedusingtheappropriateconversionfactor.TheDistributionFactorsforcylindricalandscala
illuminance have been calculated using data provided by Dr. A. R. Bean.
Allinformation,recommendations,oradvicecontainedinthisdocumentorgivenbyVandaliteLightingLtd.,oranyofitssubsidiaries,affiliates,orauthorise
representatives, whether written or oral, is given in good faith, to the best of its knowledge, and based on current procedures in effect.
TheproductsofVandaliteLightingLtd.orifapplicable,ofitssubsidiariesoraffiliatesaresoldsubjecttoGeneralConditionsofSaleprintedattherearofthe
curren
catalogueoravailableuponrequest.Nothinginthisoranyotherdocumentshallalter,varyorsupersede,oroperatetowaiveanyoftheGeneralConditionsofSale.Eac
useroftheproductsshallconvincethemselves,throughallavailablesources(includingfinishedproducttestinginitsappropriateenvironment)ofthesuitabilityofth
productssuppliedforitsownparticularpurpose.BecauseactualuseoftheproductsbytheuserisbeyondthecontrolofVandaliteLightingLtd.,itssubsidiariesan
affiliates,suchuseiswithintheexclusiveresponsibilityoftheuser.VandaliteLightingLtd.,itssubsidiariesandaffiliatescannotbeheldresponsibleforanylossincurre
throughincorrectorfaultyuseoftheproducts.Information,recommendationand/oradviceareneithermadetoinfringeonanypatents,nortograntalicenseunderan
patentorintellectualpropertyrightofVandaliteLightingLtdoranyofitssubsidiariesoraffiliatedcompanies,nortogranttherighttofileforanypatentprotection.We
hav
a policy of continuous technical development and products and / or descriptions, and / or materials may be changed without prior public announcement or warning.
Photometric Data Sheet Reference:
|