![]() ![]() V
1612
1500
114
57
116
110
Conversion Terms:
LampUF & PC
NMS 1581 x 58W T81.00
NMS 1701 x 70W T81.01
SHR NOM =1.75
Reflectances
Room Index
CWF
0.751.001.251.502.002.503.004.005.0
0.700.500.20
0.360.430.480.520.580.620.640.680.7
0.30
0.290.370.420.460.520.560.590.640.6
0.10
0.250.320.370.410.470.520.550.600.6
0.500.500.20
0.330.400.440.480.530.560.590.620.6
0.30
0.270.340.390.430.480.520.550.590.6
0.10
0.230.300.350.380.440.480.510.560.5
0.300.500.20
0.300.360.400.440.480.510.530.570.5
0.30
0.260.320.360.390.440.480.500.540.5
0.10
0.220.280.320.360.410.450.470.510.5
0.000.000.00
0.190.240.280.310.350.390.410.440.4
BZ Class
666666666
DF(F)
0.190.240.280.310.350.390.410.440.4
DF(W)
0.430.380.340.310.270.230.210.180.1
DF(C)
0.160.160.160.160.160.160.160.160.1
DF(V)
Cylindrical
0.030.050.070.080.110.130.150.190.2
DF(S)
Scalar
0.050.070.090.110.130.150.170.200.2
0.26
3260837978
1.89
0.78
2.55
0.62
0.16
Nemesis Range
Description:
Surface Zone 2 fluorescent, IP65, linear single lamp
Vandalite Lighting Ltd
Photometric Data Sheet
Cartesian Diagram
0
50
100
150
Gamma Angle
TransverseAxial
Dimensions:
(in mm)
Physical Width =
Luminous Width =
Physical Height =
Luminous Height =
Physical Length =
Luminous Length =
Flux Fraction Ratio =
SHR MAX =
SHR MAX(TR) =
CIE Flux Code =
Light Output Ratio =
Downward LOR =
Upward LOR =
/ / / /
Utilisation Factors - UF(F)
Floor Reflectance - 20%
![]() 0
137137
0
0.0000.00
5
139136
5
0.0870.00
10
138135
10
0.1730.01
15
140132
15
0.2560.03
20
139128
20
0.3350.05
25
140122
25
0.4080.08
30
140115
30
0.4750.12
35
141106
35
0.5350.16
40
14295
40
0.5850.20
45
14386
45
0.6280.24
50
14275
50
0.6630.27
55
14083
55
0.6930.31
60
13853
60
0.7160.35
65
13441
65
0.7300.38
70
12831
70
0.7390.40
75
12121
75
0.7440.41
80
11612
80
0.7460.42
85
1116
85
0.7470.43
90
1092
90
0.7470.43
95
1072
100
1042
105
952
110
811
115
631
120
451
125
311
130
201
135
111
140
81
45
80771
145
31
50
82867
150
11
55
85083
155
11
60
88260
160
11
65
91054
165
00
70
93649
170
00
75
96643
175
00
80
102834
180
00
85
111529
NM001C
Luminous Intensity Values - (cd/1000 lm)
Gamma Angle Transverse Axial
(degrees) Plane (0) Plane (90)
o
o
Angle Parallel Perpendicular
(degrees) Plane Plane
Aspect Factors
Angle Transverse Axial
(degrees) Plane Plane
Luminance Distribution (cd/m/klm)
2
TheUtilisationFactortable,BZvalues,andDistributionFactors(F)(W)&(C)havebeencalculatedinaccordancewithCIBSETechnicalMemorandumNo.5
(1980
fro
datatestedwithoutaceilingboard.TheUFvaluesneedtobecorrectedusingtheappropriateconversionfactor.TheDistributionFactorsforcylindricalandscala
illuminance have been calculated using data provided by Dr. A. R. Bean.
Allinformation,recommendations,oradvicecontainedinthisdocumentorgivenbyVandaliteLightingLtd.,oranyofitssubsidiaries,affiliates,orauthorise
representatives, whether written or oral, is given in good faith, to the best of its knowledge, and based on current procedures in effect.
TheproductsofVandaliteLightingLtd.orifapplicable,ofitssubsidiariesoraffiliatesaresoldsubjecttoGeneralConditionsofSaleprintedattherearofthe
curren
catalogueoravailableuponrequest.Nothinginthisoranyotherdocumentshallalter,varyorsupersede,oroperatetowaiveanyoftheGeneralConditionsofSale.Eac
useroftheproductsshallconvincethemselves,throughallavailablesources(includingfinishedproducttestinginitsappropriateenvironment)ofthesuitabilityofth
productssuppliedforitsownparticularpurpose.BecauseactualuseoftheproductsbytheuserisbeyondthecontrolofVandaliteLightingLtd.,itssubsidiariesan
affiliates,suchuseiswithintheexclusiveresponsibilityoftheuser.VandaliteLightingLtd.,itssubsidiariesandaffiliatescannotbeheldresponsibleforanylossincurre
throughincorrectorfaultyuseoftheproducts.Information,recommendationand/oradviceareneithermadetoinfringeonanypatents,nortograntalicenseunderan
patentorintellectualpropertyrightofVandaliteLightingLtdoranyofitssubsidiariesoraffiliatedcompanies,nortogranttherighttofileforanypatentprotection.We
hav
a policy of continuous technical development and products and / or descriptions, and / or materials may be changed without prior public announcement or warning.
Photometric Data Sheet Reference:
![]() ![]() V
1612
1500
114
57
186
180
Conversion Terms:
LampUF & PC
NMS 2582 x 58W T81.00
NMS 2702 x 70W T81.01
SHR NOM =1.75
Reflectances
Room Index
CWF
0.751.001.251.502.002.503.004.005.0
0.700.500.20
0.350.420.470.500.550.590.610.650.6
0.30
0.300.370.410.450.500.540.570.610.6
0.10
0.260.320.370.410.460.500.530.580.6
0.500.500.20
0.330.400.440.470.510.550.570.600.6
0.30
0.280.350.390.420.470.510.530.570.5
0.10
0.250.310.350.390.440.480.500.540.5
0.300.500.20
0.310.370.410.440.480.510.530.550.5
0.30
0.270.330.370.400.450.480.500.530.5
0.10
0.240.300.340.370.420.450.480.510.5
0.000.000.00
0.210.270.300.330.370.400.430.460.4
BZ Class
655666666
DF(F)
0.210.270.300.330.370.400.430.460.4
DF(W)
0.390.340.300.270.230.200.180.150.1
DF(C)
0.100.100.100.100.100.100.100.100.1
DF(V)
Cylindrical
0.030.050.070.080.110.130.150.180.2
DF(S)
Scalar
0.060.080.100.110.130.150.170.190.2
0.17
3766868571
1.78
0.71
2.21
0.60
0.10
Nemesis Range
Description:
Surface Zone 2 fluorescent, IP65, linear twin lamp
Vandalite Lighting Ltd
Photometric Data Sheet
Cartesian Diagram
0
50
100
150
200
Gamma Angle
TransverseAxial
Dimensions:
(in mm)
Physical Width =
Luminous Width =
Physical Height =
Luminous Height =
Physical Length =
Luminous Length =
Flux Fraction Ratio =
SHR MAX =
SHR MAX(TR) =
CIE Flux Code =
Light Output Ratio =
Downward LOR =
Upward LOR =
/ / / /
Utilisation Factors - UF(F)
Floor Reflectance - 20%
![]() 0
157157
0
0.0000.00
5
158158
5
0.0880.00
10
159154
10
0.1740.01
15
159151
15
0.2560.03
20
158146
20
0.3350.05
25
156140
25
0.4090.08
30
155131
30
0.4750.12
35
151122
35
0.5350.16
40
146110
40
0.5860.20
45
14098
45
0.6290.24
50
13485
50
0.6630.27
55
13872
55
0.6890.31
60
12358
60
0.7090.34
65
11747
65
0.7220.36
70
11135
70
0.7310.39
75
10224
75
0.7360.40
80
9015
80
0.7380.41
85
767
85
0.7390.42
90
683
90
0.7390.42
95
663
100
673
105
622
110
532
115
411
120
291
125
181
130
101
135
61
140
41
45
55749
145
21
50
56146
150
00
55
61444
155
00
60
58840
160
00
65
61138
165
00
70
64334
170
00
75
66930
175
00
80
68726
180
00
85
69920
NM002C
Luminous Intensity Values - (cd/1000 lm)
Gamma Angle Transverse Axial
(degrees) Plane (0) Plane (90)
o
o
Angle Parallel Perpendicular
(degrees) Plane Plane
Aspect Factors
Angle Transverse Axial
(degrees) Plane Plane
Luminance Distribution (cd/m/klm)
2
TheUtilisationFactortable,BZvalues,andDistributionFactors(F)(W)&(C)havebeencalculatedinaccordancewithCIBSETechnicalMemorandumNo.5
(1980
fro
datatestedwithoutaceilingboard.TheUFvaluesneedtobecorrectedusingtheappropriateconversionfactor.TheDistributionFactorsforcylindricalandscala
illuminance have been calculated using data provided by Dr. A. R. Bean.
Allinformation,recommendations,oradvicecontainedinthisdocumentorgivenbyVandaliteLightingLtd.,oranyofitssubsidiaries,affiliates,orauthorise
representatives, whether written or oral, is given in good faith, to the best of its knowledge, and based on current procedures in effect.
TheproductsofVandaliteLightingLtd.orifapplicable,ofitssubsidiariesoraffiliatesaresoldsubjecttoGeneralConditionsofSaleprintedattherearofthe
curren
catalogueoravailableuponrequest.Nothinginthisoranyotherdocumentshallalter,varyorsupersede,oroperatetowaiveanyoftheGeneralConditionsofSale.Eac
useroftheproductsshallconvincethemselves,throughallavailablesources(includingfinishedproducttestinginitsappropriateenvironment)ofthesuitabilityofth
productssuppliedforitsownparticularpurpose.BecauseactualuseoftheproductsbytheuserisbeyondthecontrolofVandaliteLightingLtd.,itssubsidiariesan
affiliates,suchuseiswithintheexclusiveresponsibilityoftheuser.VandaliteLightingLtd.,itssubsidiariesandaffiliatescannotbeheldresponsibleforanylossincurre
throughincorrectorfaultyuseoftheproducts.Information,recommendationand/oradviceareneithermadetoinfringeonanypatents,nortograntalicenseunderan
patentorintellectualpropertyrightofVandaliteLightingLtdoranyofitssubsidiariesoraffiliatedcompanies,nortogranttherighttofileforanypatentprotection.We
hav
a policy of continuous technical development and products and / or descriptions, and / or materials may be changed without prior public announcement or warning.
Photometric Data Sheet Reference:
|